Basic Info
  • Model NO.: ZW861D
  • Trademark: EVA LOGIK
  • Origin: Dongguan, China
  • Waterproof: Waterproof
  • Specification: 41.9* 16.9 *36.7mm
  • HS Code: 8538900000
Product Description

Introduction 

This module is designed to operate in a wall switch box or in locations where the control of an electric device is needed. It is also possible to send a signal to any system that is to be integrated with Z-wave system. Every mains powered Z-Wave enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate "RF dead-spots".

Technical data 
Z-Wave Dimmer Fixture Wall Switch Module (ZW861D)
Z-Wave Dimmer Fixture Wall Switch Module (ZW861D)

*Work with existing light switches, **NEUTRAL WIRE required**

*Slim size module with build in Z-Wave technology

*Acts as a Z-Wave repeater to extend the range

*On/Off control via Z-Wave controller, manual wall switch

*Two Pole only

Installation 

1. Before installation ensure that the voltage supply is disconnected.

2. Connect ZW861D module as shown on above diagram.

3. Place the Module in the switch box.

4. Arrange the antenna (tips are presented as above diagrams)

 Do not cut or shorten the antenna - its length is perfectly matched to the band in which the system operates; Locate the antenna as far from metal elements as possible (connecting wires, bracket rings, etc.) in order to prevent interferences. 

5. Connect the device in accordance with the wiring diagram presented in Wiring diagram. Switch on 230V of the mains voltage.

6. For "Add" in a network: Put the Z-wave interface controller into "Add" mode, and following its instruction to add the ZW861D to your controller. To get in the "Add" mode, the distance between ZW861D module and controller is suggested to be in one meter. Quickly pressing the learn switch of ZW861D three times or press the mechanical panel K1 three times at least & release to be included. After added in Z-wave network, the indicate LED always lighting.

7. For "Remove" from a network: set up the Z-wave interface controller into "Remove" mode, and following its instruction to delete the ZW861D from your controller. Press the learn switch of ZW861D three times or press the mechanical panel K1 three times at least  & release to be excluded. After remove from Z-wave net work indicate LED off.

8. For "Condition" which is controlling other devices of Z-wave system, Condition ensures direct transfer of control commands between devices, and is performed without participation of the main controller. e.g. Dimmer, Switch (ON-OFF), Door/Window sensor, PIR, Shutter or scene (scene may be controlled only through the ZE300 gateway).

Safety & Maintenance Instruction

-       Make sure that all electric connections and connection cables meet the pertaining regulations and are in conformity with the operating instruction.

-       Do not overload electrical outlets or extension cords, fire or electric shocks can be the result.

-       Please contact an expert in case you have any doubts about the mode of operation, the safety or connecting the appliances.

-       Keep all parts away from young children's reach.

-       Do not store this item on wet, very cold or warm places, this can damage the electronic circuit boards.

-       Avoid dropping or shocks, this can damage the electronic boards.

-       Never replace damaged power cables yourself! In such case, remove them from the net and take the devices to a workshop.

-       Wireless system are subject to interference from cordless phones, microwaves, and other wireless devices during installation and operation. 

Maintenance

The devices are maintenance-free, so never open them. The guarantee becomes void when you open the appliance. Only clean the outside of the devices with a soft, dry cloth or a brush. Prior to cleaning, remove the devices from all voltage sources.

NOTE

Do not use any carboxylic cleaning agents or petrol, alcohol or similar. These will attack the surface of devices. Besides, the vapors are hazardous to your health and explosive. Do not use any sharp edged tools, screw drivers, metal brushes or similar for cleaning.

Warranty 1 year
Shipping &Packing
Z-Wave Dimmer Fixture Wall Switch Module (ZW861D)


Company Information
Z-Wave Dimmer Fixture Wall Switch Module (ZW861D)
Z-Wave Dimmer Fixture Wall Switch Module (ZW861D)

 

Send your message to this supplier
Avatar
Mrs. Irene
sale
*From:
To: Mrs. Irene
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category